NC-GEN - Compact PSA nitrogen generators
The NC-GEN compact nitrogen generators extract the available nitrogen in the ambient air from the other gases by applying the Pressure Swing Adsorption (PSA) technology. During the PSA process compressed, cleaned ambient air is led to a molecular sieve bed, which allows the nitrogen to pass through as product gas, but adsorbs other gases. The sieve releases the adsorbed gases to the atmosphere when the outlet valve is closed and the bed pressure returns to ambient pressure. Subsequently, the bed will be purged with nitrogen before fresh compressed air will enter for a new production cycle. In order to guarantee a constant product flow nitrogen generators use two molecular sieve beds, which alternatively switch between the adsorption and the regeneration phase.
Characteristics
operating pressure | 2,5 - 8,5 bar |
operating temperature range | 5 to 35 °C |
ambient air temperature range | up to 40 °C |
dew points (atmospheric) | < -40 °C |
N2 capacity | 0,14 to 14,2 Nm3/h |
N2 purity | up to 99,999 % |
Applications
• Inerting of Flammable Liquids
• Laser Cutting
• Re-flow and Wave Soldering of PCBs
• UV-Curing of Coatings
• Food processing
- pre-filter with automatic drain AOK16B and manometer PDI 16 (N-GEN 03-200), MDM 40 (N-GEN250-400),
- after-filter with manual drain MCD and manometer PDI 16 (N-GEN 03-200), MDM 40 (N-GEN250-400).
Technical data